RedFuel SL31 Installation Manual

Browse online or download Installation Manual for Electric laundry dryers RedFuel SL31. RedFuel SL31 Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SL20 / SL31 / SL50 / SL75
Installation/Operator Manual
WARNING: For your safety the
information in this manual must be
followed to minimize the risk of fire or
explosion and to prevent property
damage, personal injury or death.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your
building.
Clear the room, building or area of all
occupants.
Immediately call your gas supplier
from a neighbors phone. Follow the
gas suppliers instructions.
If you cannot reach your gas supplier,
call the fire department.
Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d’incendie ou d’explosion ou pour éviter
tout dommage matériel, toute blessure ou
la mort.
Ne pas entreposer ni utiliser d’essence
ni d’autres vapeurs ou liquides
inflammables à proximité de cet
appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
Ne pas tenter d’allumer d’appareils.
Ne touchez à aucun interrupteur. Ne
pas vous servir des téléphones se
trouvant dans le bâtiment.
Évacuez la pièce, le bâtiment ou la
zone.
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service
des incendies.
— L’installation et l’entretien doivent être
assurés par un installateur ou un service
d’entretien qualifié ou par le fournisseur
de gaz.
ADC Part No. 113403-14
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781 USA
Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447
e-mail: techsupport@amdry.com
www.amdry.com
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - Installation/Operator Manual

SL20 / SL31 / SL50 / SL75Installation/Operator ManualWARNING: For your safety theinformation in this manual must befollowed to minimize the risk of f

Page 2 - IMPORTANT

10 American Dryer Corp. 113403-14SL50 Specifications _______________________________________________________________!NoteThe manufacturer reserves the

Page 3 - Table of Contents ________

113403-14 www.amdry.com 11SL50 Specifications _______________________________________________________________

Page 4

12 American Dryer Corp. 113403-14!NoteThe manufacturer reserves the right to make changes in specifications at any time without notice or obligation.M

Page 5

113403-14 www.amdry.com 13SL75 Specifications _______________________________________________________________

Page 6

14 American Dryer Corp. 113403-14!Installation Procedures ______________Installation should be performed by competent professionalin accordance with l

Page 7 - 113403-14 www.amdry.com 7

113403-14 www.amdry.com 15Domestic Type I(SL20, SL31, SL50 Only)!!!EXAMPLE: For SL50, 2 unrestricted openings measuring6-inches by 24-inches (15.24 cm

Page 8 - Electric

16 American Dryer Corp. 113403-14NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm)larger than the duct (all the way around). The d

Page 9 - 113403-14 www.amdry.com 9

113403-14 www.amdry.com 17ImportantNo more than 4 dryers should be connected to 1main common duct.The illustration below shows the minimum cross-secti

Page 10 - GasElectricSteam

18 American Dryer Corp. 113403-14Electric Models OnlyAll electrically heated dryers must be connected to the electricservice shown on the dryer’s data

Page 11 - 113403-14 www.amdry.com 11

113403-14 www.amdry.com 19GroundingA ground (earth) connection must be provided and installedin accordance with local, state, and national regulations

Page 12

2 American Dryer Corp. 113403-14“IMPORTANT NOTE TO PURCHASER”Information must be obtained from your local gas supplier on theinstructions to be follow

Page 13 - 113403-14 www.amdry.com 13

20 American Dryer Corp. 113403-14!!Gas Information ______________________It is your responsibility to have all plumbing connections,materials, and wor

Page 14

113403-14 www.amdry.com 21Gas Specifications for Non-CE and Non-AGA Approved Dryers**ModelGasTypeNominalHeating ValueSupplyPressureGrossHeat InputOrif

Page 15 - Important

22 American Dryer Corp. 113403-14Piping/ConnectionsCE and Australian dryer connections will be B.S.P.T., all others will be N.P.T.There should be a mi

Page 16

113403-14 www.amdry.com 23Converting from One Familyof Gas to Another _____________________Warning (CE Dryers)This appliance must only be operated wit

Page 17 - A = SL20 4-inch (10.16 cm)

24 American Dryer Corp. 113403-14!!!Regulated Gas ValveRefer to “Gas Pressure Adjustment” on this page to adjustthe gas valve to the appropriate burne

Page 18 - Gas and Steam Models Only

113403-14 www.amdry.com 25!!Gas Pressure Testing _________________For proper operation, the gas pressure must be correct,consistent and maintained at

Page 19

26 American Dryer Corp. 113403-14!!!!!Steam Requirements – High PressureShaded areas are stated in metric equivalents* The minimum operating pressure

Page 20

113403-14 www.amdry.com 27!!!!ImportantFlexible supply line/coupling must be used.Solenoid valve failure due to hard plumbingconnections will void war

Page 21

28 American Dryer Corp. 113403-14! NOTES______________________________________________________________________________________________________________

Page 22 - 3/8” 1/2” 1/2” 1/2”

113403-14 www.amdry.com 29Service/Parts Information ____________ServiceService must be performed by a qualified trained technician.If service is requi

Page 23 - Converting from One Family

113403-14 www.amdry.com 3IMPORTANTYou must disconnect and lockout the electricsupply and the gas supply or the steam supplybefore any covers or guards

Page 24 - Edge #2 for adjustment screw

30 American Dryer Corp. 113403-14Routine Maintenance _________________CleaningA program and/or schedule should be established forperiodic inspection,

Page 25 - Steam Coil pH Level

113403-14 www.amdry.com 31CE LabelData Label Information ____________________________________________________________Standard LabelWhen contacting ADC

Page 26 - Operating Steam Pressure

ADC Part No. 113403 14 - 02/08/08 - 0

Page 27

4 American Dryer Corp. 113403-14Safety Precautions ___________________WarningFor your safety, the information in this manualmust be followed to minimi

Page 28 - Non-Coin Models

113403-14 www.amdry.com 5The “Cool Down” Cycle of tumble dryers should be used toreduce the temperature of the items. They should not beremoved from

Page 29

6 American Dryer Corp. 113403-14SL20 Specifications _______________________________________________________________!NoteThe manufacturer reserves the

Page 30

113403-14 www.amdry.com 7SL20 Specifications _______________________________________________________________

Page 31 - AGA Label

8 American Dryer Corp. 113403-14SL31 Specifications _______________________________________________________________!NoteThe manufacturer reserves the

Page 32

113403-14 www.amdry.com 9SL31 Specifications _______________________________________________________________

Comments to this Manuals